Provides a Express Connect Physical Connection resource.

For information about Express Connect Physical Connection and how to use it, see What is Physical Connection.

NOTE: Available since v1.132.0.

Example Usage

Basic Usage

import * as pulumi from "@pulumi/pulumi";
import * as alicloud from "@pulumi/alicloud";

const domestic = new alicloud.expressconnect.PhysicalConnection("domestic", {
    accessPointId: "ap-cn-hangzhou-yh-B",
    lineOperator: "CT",
    peerLocation: "example_value",
    physicalConnectionName: "example_value",
    type: "VPC",
    description: "my domestic connection",
    portType: "1000Base-LX",
    bandwidth: "100",
});
const international = new alicloud.expressconnect.PhysicalConnection("international", {
    accessPointId: "ap-sg-singpore-A",
    lineOperator: "Other",
    peerLocation: "example_value",
    physicalConnectionName: "example_value",
    type: "VPC",
    description: "my domestic connection",
    portType: "1000Base-LX",
    bandwidth: "100",
});
Copy
import pulumi
import pulumi_alicloud as alicloud

domestic = alicloud.expressconnect.PhysicalConnection("domestic",
    access_point_id="ap-cn-hangzhou-yh-B",
    line_operator="CT",
    peer_location="example_value",
    physical_connection_name="example_value",
    type="VPC",
    description="my domestic connection",
    port_type="1000Base-LX",
    bandwidth="100")
international = alicloud.expressconnect.PhysicalConnection("international",
    access_point_id="ap-sg-singpore-A",
    line_operator="Other",
    peer_location="example_value",
    physical_connection_name="example_value",
    type="VPC",
    description="my domestic connection",
    port_type="1000Base-LX",
    bandwidth="100")
Copy
package main

import (
	"github.com/pulumi/pulumi-alicloud/sdk/v3/go/alicloud/expressconnect"
	"github.com/pulumi/pulumi/sdk/v3/go/pulumi"
)

func main() {
	pulumi.Run(func(ctx *pulumi.Context) error {
		_, err := expressconnect.NewPhysicalConnection(ctx, "domestic", &expressconnect.PhysicalConnectionArgs{
			AccessPointId:          pulumi.String("ap-cn-hangzhou-yh-B"),
			LineOperator:           pulumi.String("CT"),
			PeerLocation:           pulumi.String("example_value"),
			PhysicalConnectionName: pulumi.String("example_value"),
			Type:                   pulumi.String("VPC"),
			Description:            pulumi.String("my domestic connection"),
			PortType:               pulumi.String("1000Base-LX"),
			Bandwidth:              pulumi.String("100"),
		})
		if err != nil {
			return err
		}
		_, err = expressconnect.NewPhysicalConnection(ctx, "international", &expressconnect.PhysicalConnectionArgs{
			AccessPointId:          pulumi.String("ap-sg-singpore-A"),
			LineOperator:           pulumi.String("Other"),
			PeerLocation:           pulumi.String("example_value"),
			PhysicalConnectionName: pulumi.String("example_value"),
			Type:                   pulumi.String("VPC"),
			Description:            pulumi.String("my domestic connection"),
			PortType:               pulumi.String("1000Base-LX"),
			Bandwidth:              pulumi.String("100"),
		})
		if err != nil {
			return err
		}
		return nil
	})
}
Copy
using System.Collections.Generic;
using System.Linq;
using Pulumi;
using AliCloud = Pulumi.AliCloud;

return await Deployment.RunAsync(() => 
{
    var domestic = new AliCloud.ExpressConnect.PhysicalConnection("domestic", new()
    {
        AccessPointId = "ap-cn-hangzhou-yh-B",
        LineOperator = "CT",
        PeerLocation = "example_value",
        PhysicalConnectionName = "example_value",
        Type = "VPC",
        Description = "my domestic connection",
        PortType = "1000Base-LX",
        Bandwidth = "100",
    });

    var international = new AliCloud.ExpressConnect.PhysicalConnection("international", new()
    {
        AccessPointId = "ap-sg-singpore-A",
        LineOperator = "Other",
        PeerLocation = "example_value",
        PhysicalConnectionName = "example_value",
        Type = "VPC",
        Description = "my domestic connection",
        PortType = "1000Base-LX",
        Bandwidth = "100",
    });

});
Copy
package generated_program;

import com.pulumi.Context;
import com.pulumi.Pulumi;
import com.pulumi.core.Output;
import com.pulumi.alicloud.expressconnect.PhysicalConnection;
import com.pulumi.alicloud.expressconnect.PhysicalConnectionArgs;
import java.util.List;
import java.util.ArrayList;
import java.util.Map;
import java.io.File;
import java.nio.file.Files;
import java.nio.file.Paths;

public class App {
    public static void main(String[] args) {
        Pulumi.run(App::stack);
    }

    public static void stack(Context ctx) {
        var domestic = new PhysicalConnection("domestic", PhysicalConnectionArgs.builder()
            .accessPointId("ap-cn-hangzhou-yh-B")
            .lineOperator("CT")
            .peerLocation("example_value")
            .physicalConnectionName("example_value")
            .type("VPC")
            .description("my domestic connection")
            .portType("1000Base-LX")
            .bandwidth(100)
            .build());

        var international = new PhysicalConnection("international", PhysicalConnectionArgs.builder()
            .accessPointId("ap-sg-singpore-A")
            .lineOperator("Other")
            .peerLocation("example_value")
            .physicalConnectionName("example_value")
            .type("VPC")
            .description("my domestic connection")
            .portType("1000Base-LX")
            .bandwidth(100)
            .build());

    }
}
Copy
resources:
  domestic:
    type: alicloud:expressconnect:PhysicalConnection
    properties:
      accessPointId: ap-cn-hangzhou-yh-B
      lineOperator: CT
      peerLocation: example_value
      physicalConnectionName: example_value
      type: VPC
      description: my domestic connection
      portType: 1000Base-LX
      bandwidth: 100
  international:
    type: alicloud:expressconnect:PhysicalConnection
    properties:
      accessPointId: ap-sg-singpore-A
      lineOperator: Other
      peerLocation: example_value
      physicalConnectionName: example_value
      type: VPC
      description: my domestic connection
      portType: 1000Base-LX
      bandwidth: 100
Copy

Create PhysicalConnection Resource

Resources are created with functions called constructors. To learn more about declaring and configuring resources, see Resources.

Constructor syntax

new PhysicalConnection(name: string, args: PhysicalConnectionArgs, opts?: CustomResourceOptions);
@overload
def PhysicalConnection(resource_name: str,
                       args: PhysicalConnectionArgs,
                       opts: Optional[ResourceOptions] = None)

@overload
def PhysicalConnection(resource_name: str,
                       opts: Optional[ResourceOptions] = None,
                       line_operator: Optional[str] = None,
                       access_point_id: Optional[str] = None,
                       period: Optional[int] = None,
                       description: Optional[str] = None,
                       circuit_code: Optional[str] = None,
                       peer_location: Optional[str] = None,
                       bandwidth: Optional[str] = None,
                       physical_connection_name: Optional[str] = None,
                       port_type: Optional[str] = None,
                       pricing_cycle: Optional[str] = None,
                       redundant_physical_connection_id: Optional[str] = None,
                       status: Optional[str] = None,
                       type: Optional[str] = None)
func NewPhysicalConnection(ctx *Context, name string, args PhysicalConnectionArgs, opts ...ResourceOption) (*PhysicalConnection, error)
public PhysicalConnection(string name, PhysicalConnectionArgs args, CustomResourceOptions? opts = null)
public PhysicalConnection(String name, PhysicalConnectionArgs args)
public PhysicalConnection(String name, PhysicalConnectionArgs args, CustomResourceOptions options)
type: alicloud:expressconnect:PhysicalConnection
properties: # The arguments to resource properties.
options: # Bag of options to control resource's behavior.

Parameters

name This property is required. string
The unique name of the resource.
args This property is required. PhysicalConnectionArgs
The arguments to resource properties.
opts CustomResourceOptions
Bag of options to control resource's behavior.
resource_name This property is required. str
The unique name of the resource.
args This property is required. PhysicalConnectionArgs
The arguments to resource properties.
opts ResourceOptions
Bag of options to control resource's behavior.
ctx Context
Context object for the current deployment.
name This property is required. string
The unique name of the resource.
args This property is required. PhysicalConnectionArgs
The arguments to resource properties.
opts ResourceOption
Bag of options to control resource's behavior.
name This property is required. string
The unique name of the resource.
args This property is required. PhysicalConnectionArgs
The arguments to resource properties.
opts CustomResourceOptions
Bag of options to control resource's behavior.
name This property is required. String
The unique name of the resource.
args This property is required. PhysicalConnectionArgs
The arguments to resource properties.
options CustomResourceOptions
Bag of options to control resource's behavior.

Constructor example

The following reference example uses placeholder values for all input properties.

var physicalConnectionResource = new AliCloud.ExpressConnect.PhysicalConnection("physicalConnectionResource", new()
{
    LineOperator = "string",
    AccessPointId = "string",
    Period = 0,
    Description = "string",
    CircuitCode = "string",
    PeerLocation = "string",
    Bandwidth = "string",
    PhysicalConnectionName = "string",
    PortType = "string",
    PricingCycle = "string",
    RedundantPhysicalConnectionId = "string",
    Status = "string",
    Type = "string",
});
Copy
example, err := expressconnect.NewPhysicalConnection(ctx, "physicalConnectionResource", &expressconnect.PhysicalConnectionArgs{
	LineOperator:                  pulumi.String("string"),
	AccessPointId:                 pulumi.String("string"),
	Period:                        pulumi.Int(0),
	Description:                   pulumi.String("string"),
	CircuitCode:                   pulumi.String("string"),
	PeerLocation:                  pulumi.String("string"),
	Bandwidth:                     pulumi.String("string"),
	PhysicalConnectionName:        pulumi.String("string"),
	PortType:                      pulumi.String("string"),
	PricingCycle:                  pulumi.String("string"),
	RedundantPhysicalConnectionId: pulumi.String("string"),
	Status:                        pulumi.String("string"),
	Type:                          pulumi.String("string"),
})
Copy
var physicalConnectionResource = new PhysicalConnection("physicalConnectionResource", PhysicalConnectionArgs.builder()
    .lineOperator("string")
    .accessPointId("string")
    .period(0)
    .description("string")
    .circuitCode("string")
    .peerLocation("string")
    .bandwidth("string")
    .physicalConnectionName("string")
    .portType("string")
    .pricingCycle("string")
    .redundantPhysicalConnectionId("string")
    .status("string")
    .type("string")
    .build());
Copy
physical_connection_resource = alicloud.expressconnect.PhysicalConnection("physicalConnectionResource",
    line_operator="string",
    access_point_id="string",
    period=0,
    description="string",
    circuit_code="string",
    peer_location="string",
    bandwidth="string",
    physical_connection_name="string",
    port_type="string",
    pricing_cycle="string",
    redundant_physical_connection_id="string",
    status="string",
    type="string")
Copy
const physicalConnectionResource = new alicloud.expressconnect.PhysicalConnection("physicalConnectionResource", {
    lineOperator: "string",
    accessPointId: "string",
    period: 0,
    description: "string",
    circuitCode: "string",
    peerLocation: "string",
    bandwidth: "string",
    physicalConnectionName: "string",
    portType: "string",
    pricingCycle: "string",
    redundantPhysicalConnectionId: "string",
    status: "string",
    type: "string",
});
Copy
type: alicloud:expressconnect:PhysicalConnection
properties:
    accessPointId: string
    bandwidth: string
    circuitCode: string
    description: string
    lineOperator: string
    peerLocation: string
    period: 0
    physicalConnectionName: string
    portType: string
    pricingCycle: string
    redundantPhysicalConnectionId: string
    status: string
    type: string
Copy

PhysicalConnection Resource Properties

To learn more about resource properties and how to use them, see Inputs and Outputs in the Architecture and Concepts docs.

Inputs

In Python, inputs that are objects can be passed either as argument classes or as dictionary literals.

The PhysicalConnection resource accepts the following input properties:

AccessPointId
This property is required.
Changes to this property will trigger replacement.
string
The access point ID of the Express Connect circuit.
LineOperator This property is required. string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
Bandwidth string
The maximum bandwidth of the hosted connection.
CircuitCode string
The circuit code of the Express Connect circuit.
Description string
The description of the Express Connect circuit.
PeerLocation string
The geographical location of the data center.
Period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
PhysicalConnectionName string
The name of the Express Connect circuit.
PortType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

PricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

RedundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
Status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
Type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
AccessPointId
This property is required.
Changes to this property will trigger replacement.
string
The access point ID of the Express Connect circuit.
LineOperator This property is required. string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
Bandwidth string
The maximum bandwidth of the hosted connection.
CircuitCode string
The circuit code of the Express Connect circuit.
Description string
The description of the Express Connect circuit.
PeerLocation string
The geographical location of the data center.
Period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
PhysicalConnectionName string
The name of the Express Connect circuit.
PortType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

PricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

RedundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
Status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
Type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId
This property is required.
Changes to this property will trigger replacement.
String
The access point ID of the Express Connect circuit.
lineOperator This property is required. String
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
bandwidth String
The maximum bandwidth of the hosted connection.
circuitCode String
The circuit code of the Express Connect circuit.
description String
The description of the Express Connect circuit.
peerLocation String
The geographical location of the data center.
period Integer
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName String
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. String

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle String

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. String
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status String
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. String
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId
This property is required.
Changes to this property will trigger replacement.
string
The access point ID of the Express Connect circuit.
lineOperator This property is required. string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
bandwidth string
The maximum bandwidth of the hosted connection.
circuitCode string
The circuit code of the Express Connect circuit.
description string
The description of the Express Connect circuit.
peerLocation string
The geographical location of the data center.
period number
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName string
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
access_point_id
This property is required.
Changes to this property will trigger replacement.
str
The access point ID of the Express Connect circuit.
line_operator This property is required. str
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
bandwidth str
The maximum bandwidth of the hosted connection.
circuit_code str
The circuit code of the Express Connect circuit.
description str
The description of the Express Connect circuit.
peer_location str
The geographical location of the data center.
period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physical_connection_name str
The name of the Express Connect circuit.
port_type Changes to this property will trigger replacement. str

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricing_cycle str

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundant_physical_connection_id Changes to this property will trigger replacement. str
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status str
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. str
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId
This property is required.
Changes to this property will trigger replacement.
String
The access point ID of the Express Connect circuit.
lineOperator This property is required. String
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
bandwidth String
The maximum bandwidth of the hosted connection.
circuitCode String
The circuit code of the Express Connect circuit.
description String
The description of the Express Connect circuit.
peerLocation String
The geographical location of the data center.
period Number
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName String
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. String

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle String

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. String
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status String
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. String
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.

Outputs

All input properties are implicitly available as output properties. Additionally, the PhysicalConnection resource produces the following output properties:

Id string
The provider-assigned unique ID for this managed resource.
OrderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
Id string
The provider-assigned unique ID for this managed resource.
OrderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
id String
The provider-assigned unique ID for this managed resource.
orderId String
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
id string
The provider-assigned unique ID for this managed resource.
orderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
id str
The provider-assigned unique ID for this managed resource.
order_id str
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
id String
The provider-assigned unique ID for this managed resource.
orderId String
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.

Look up Existing PhysicalConnection Resource

Get an existing PhysicalConnection resource’s state with the given name, ID, and optional extra properties used to qualify the lookup.

public static get(name: string, id: Input<ID>, state?: PhysicalConnectionState, opts?: CustomResourceOptions): PhysicalConnection
@staticmethod
def get(resource_name: str,
        id: str,
        opts: Optional[ResourceOptions] = None,
        access_point_id: Optional[str] = None,
        bandwidth: Optional[str] = None,
        circuit_code: Optional[str] = None,
        description: Optional[str] = None,
        line_operator: Optional[str] = None,
        order_id: Optional[str] = None,
        peer_location: Optional[str] = None,
        period: Optional[int] = None,
        physical_connection_name: Optional[str] = None,
        port_type: Optional[str] = None,
        pricing_cycle: Optional[str] = None,
        redundant_physical_connection_id: Optional[str] = None,
        status: Optional[str] = None,
        type: Optional[str] = None) -> PhysicalConnection
func GetPhysicalConnection(ctx *Context, name string, id IDInput, state *PhysicalConnectionState, opts ...ResourceOption) (*PhysicalConnection, error)
public static PhysicalConnection Get(string name, Input<string> id, PhysicalConnectionState? state, CustomResourceOptions? opts = null)
public static PhysicalConnection get(String name, Output<String> id, PhysicalConnectionState state, CustomResourceOptions options)
resources:  _:    type: alicloud:expressconnect:PhysicalConnection    get:      id: ${id}
name This property is required.
The unique name of the resulting resource.
id This property is required.
The unique provider ID of the resource to lookup.
state
Any extra arguments used during the lookup.
opts
A bag of options that control this resource's behavior.
resource_name This property is required.
The unique name of the resulting resource.
id This property is required.
The unique provider ID of the resource to lookup.
name This property is required.
The unique name of the resulting resource.
id This property is required.
The unique provider ID of the resource to lookup.
state
Any extra arguments used during the lookup.
opts
A bag of options that control this resource's behavior.
name This property is required.
The unique name of the resulting resource.
id This property is required.
The unique provider ID of the resource to lookup.
state
Any extra arguments used during the lookup.
opts
A bag of options that control this resource's behavior.
name This property is required.
The unique name of the resulting resource.
id This property is required.
The unique provider ID of the resource to lookup.
state
Any extra arguments used during the lookup.
opts
A bag of options that control this resource's behavior.
The following state arguments are supported:
AccessPointId Changes to this property will trigger replacement. string
The access point ID of the Express Connect circuit.
Bandwidth string
The maximum bandwidth of the hosted connection.
CircuitCode string
The circuit code of the Express Connect circuit.
Description string
The description of the Express Connect circuit.
LineOperator string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
OrderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
PeerLocation string
The geographical location of the data center.
Period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
PhysicalConnectionName string
The name of the Express Connect circuit.
PortType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

PricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

RedundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
Status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
Type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
AccessPointId Changes to this property will trigger replacement. string
The access point ID of the Express Connect circuit.
Bandwidth string
The maximum bandwidth of the hosted connection.
CircuitCode string
The circuit code of the Express Connect circuit.
Description string
The description of the Express Connect circuit.
LineOperator string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
OrderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
PeerLocation string
The geographical location of the data center.
Period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
PhysicalConnectionName string
The name of the Express Connect circuit.
PortType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

PricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

RedundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
Status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
Type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId Changes to this property will trigger replacement. String
The access point ID of the Express Connect circuit.
bandwidth String
The maximum bandwidth of the hosted connection.
circuitCode String
The circuit code of the Express Connect circuit.
description String
The description of the Express Connect circuit.
lineOperator String
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
orderId String
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
peerLocation String
The geographical location of the data center.
period Integer
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName String
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. String

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle String

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. String
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status String
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. String
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId Changes to this property will trigger replacement. string
The access point ID of the Express Connect circuit.
bandwidth string
The maximum bandwidth of the hosted connection.
circuitCode string
The circuit code of the Express Connect circuit.
description string
The description of the Express Connect circuit.
lineOperator string
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
orderId string
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
peerLocation string
The geographical location of the data center.
period number
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName string
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. string

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle string

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. string
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status string
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. string
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
access_point_id Changes to this property will trigger replacement. str
The access point ID of the Express Connect circuit.
bandwidth str
The maximum bandwidth of the hosted connection.
circuit_code str
The circuit code of the Express Connect circuit.
description str
The description of the Express Connect circuit.
line_operator str
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
order_id str
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
peer_location str
The geographical location of the data center.
period int
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physical_connection_name str
The name of the Express Connect circuit.
port_type Changes to this property will trigger replacement. str

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricing_cycle str

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundant_physical_connection_id Changes to this property will trigger replacement. str
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status str
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. str
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.
accessPointId Changes to this property will trigger replacement. String
The access point ID of the Express Connect circuit.
bandwidth String
The maximum bandwidth of the hosted connection.
circuitCode String
The circuit code of the Express Connect circuit.
description String
The description of the Express Connect circuit.
lineOperator String
The connectivity provider of the Express Connect circuit. Valid values:

  • CT: China Telecom.
  • CU: China Unicom.
  • CM: China Mobile.
  • CO: Other connectivity providers in the Chinese mainland.
  • Equinix: Equinix.
  • Other: Other connectivity providers outside the Chinese mainland.
orderId String
The ID of the order that is placed. Note: order_id takes effect only if status is set to Enabled.
peerLocation String
The geographical location of the data center.
period Number
The subscription duration. Valid values:

  • If pricing_cycle is set to Month. Valid values: 1 to 9.
  • If pricing_cycle is set to Year. Valid values: 1 to 5.
physicalConnectionName String
The name of the Express Connect circuit.
portType Changes to this property will trigger replacement. String

The port type of the Express Connect circuit. Valid values:

  • 100Base-T: 100 Mbit/s copper Ethernet port.
  • 1000Base-T: 1000 Mbit/s copper Ethernet port.
  • 1000Base-LX: 1000 Mbit/s single-mode optical port (10 km).
  • 10GBase-T: 10000 Mbit/s copper Ethernet port.
  • 10GBase-LR: 10000 Mbit/s single-mode optical port (10 km).
  • 40GBase-LR: 40000 Mbit/s single-mode optical port.
  • 100GBase-LR: 100000 Mbit/s single-mode optical port.

NOTE: From version 1.185.0, port_type can be set to 40GBase-LR, 100GBase-LR. From version 1.230.1, port_type cannot be modified.

pricingCycle String

The billing cycle of the subscription. Default value: Month. Valid values: Month, Year.

NOTE: period and pricing_cycle are valid only when status is set to Enabled.

redundantPhysicalConnectionId Changes to this property will trigger replacement. String
The ID of the redundant Express Connect circuit. NOTE: From version 1.230.1, redundant_physical_connection_id cannot be modified.
status String
The status of the Express Connect circuit. Valid values: Confirmed, Enabled, Canceled, Terminated. NOTE: From version 1.230.1, status can be set to Confirmed. If you want to set status to Enabled, period must be set.
type Changes to this property will trigger replacement. String
The type of Express Connect circuit. Default value: VPC. Valid values: VPC.

Import

Express Connect Physical Connection can be imported using the id, e.g.

$ pulumi import alicloud:expressconnect/physicalConnection:PhysicalConnection example <id>
Copy

To learn more about importing existing cloud resources, see Importing resources.

Package Details

Repository
Alibaba Cloud pulumi/pulumi-alicloud
License
Apache-2.0
Notes
This Pulumi package is based on the alicloud Terraform Provider.